Back to Electronics Cookbook Back to Smart&Small  

 

4 Channel Precision Current Loop.

  • 4 passive (power supplied by loop) current loop receivers.
  • 4 - 20 mA input.
  • Low nonlinearity: 0.1 %.
  • Individual galvanic isolation.
  • 12-bit resolution.
  • 50 ksps max. sampling rate.
  • SPI interface.
  • Schematic diagram. Click to enlarge.



    PCAD2006 Schematic file. Click to download.



     